Amplifier Module for Strain Gage and Potentiometric Sensors
Model 9243

built-in calibration, potential separation, configurable by DIP-switches, easy installation on DIN mounting rails, optionally version with  protection class IP65

 
 
9243.jpg

Print page

Add to notepad

Download data sheet  (223.50 KB)

Download data sheet
Print page
Add to notepad
  • Accuracy < 0.05 %
  • Outputs ± 5 V, ±10 V and 0 (4) - 20 mA
  • 6 wire technique
  • Isolation between signal and power supply
  • Cut-off frequency 1 kHz, optional 4 kHz
  • Configuration via DIP switches
  • Easy installation on DIN mounting rail

  • Accuracy < 0.05 %
  • Outputs ± 5 V, ±10 V and 0 (4) - 20 mA
  • 6 wire technique
  • Isolation between signal and power supply
  • Cut-off frequency 1 kHz, optional 4 kHz
  • Configuration via DIP switches
  • Easy installation on DIN mounting rail

The amplifier module model 9243 is used wherever measurement signals from strain gauges, potentiometric sensors or DC/DC sensors have to be converted into standard signals. Simply by mounting on conventional DIN-mount rails, it is possible to position the amplifier module on location, in the proximity of the sensor. Especially for rough environments a IP65 version is available.

 

The broad auxiliary power range and the choice between AC or DC permits operation on standard power supplies used in switch gear cabinets. A highly precise reference voltage source is built-in for calibration purposes. A calibrating shunt can also be connected via two separate terminals. This permits deliberate detuning of a strain gauge sensor for calibration or merely to check the measuring chain.


Application

The amplifier module model 9243 is used wherever measurement signals from strain gauges, potentiometric sensors or DC/DC sensors have to be converted into standard signals. Simply by mounting on conventional DIN-mount rails, it is possible to position the amplifier module on location, in the proximity of the sensor. Especially for rough environments a IP65 version is available.

 

The broad auxiliary power range and the choice between AC or DC permits operation on standard power supplies used in switch gear cabinets. A highly precise reference voltage source is built-in for calibration purposes. A calibrating shunt can also be connected via two separate terminals. This permits deliberate detuning of a strain gauge sensor for calibration or merely to check the measuring chain.

A highly accurate precision amplifier performs the amplification of the sensor signal being applied. The necessary gain factor is adjusted coarsely with DIP switches while fine-tuning is carried out by using a potentiometer. Current and voltage outputs are available simultaneously. The sensor excitation is performed by the amplifier module itself so that no additional voltage source is required. It can also be set in steps of 2.5 V, 5 V, 10 V using DIP switches. The maximum feed current of 35 mA permits parallel connection of several strain gages, e.g. for the addition of measurement variables. Measurement errors brought about by varying line lengths or due to temperature fluctuations effecting the sensor cable are avoided by having probe lines measuring the actual feed voltage directly on site at the sensor itself (6 wire technology). Fluctuations are immediately corrected electronically. The cut-off frequency of the amplifier can be switched between 10 Hz and 1 kHz. The DIP switches for configuring the entire device are found easily accessible, under a cover.


Description

A highly accurate precision amplifier performs the amplification of the sensor signal being applied. The necessary gain factor is adjusted coarsely with DIP switches while fine-tuning is carried out by using a potentiometer. Current and voltage outputs are available simultaneously. The sensor excitation is performed by the amplifier module itself so that no additional voltage source is required. It can also be set in steps of 2.5 V, 5 V, 10 V using DIP switches. The maximum feed current of 35 mA permits parallel connection of several strain gages, e.g. for the addition of measurement variables. Measurement errors brought about by varying line lengths or due to temperature fluctuations effecting the sensor cable are avoided by having probe lines measuring the actual feed voltage directly on site at the sensor itself (6 wire technology). Fluctuations are immediately corrected electronically. The cut-off frequency of the amplifier can be switched between 10 Hz and 1 kHz. The DIP switches for configuring the entire device are found easily accessible, under a cover.

 

Select your country and

Your favourite language

Deutsch English

Exhibitions in Germany

Flag_Deutschland.jpg

New Publication
DIGIFORCE® brochure

The new brochure on process monitoring in production is now available.

BR_9306_9310_EN.jpg

Full to the brim with application examples and relevant information... read more on

Product site 9306Product site 9306
Product site 9310Product site 9310

Contact person

Product responsibility:

Marco Völlinger

Phone: +49-7224-645-18

marco.voellinger@burster.commarco.voellinger@burster.com

Product responsibility:

Guy Beaho

Phone: +49-7224-645-45

guy.beaho@burster.comguy.beaho@burster.com

My notepad