button_products.gif (3941 Byte)
 

Calibration Resistor
Model 1240

 

haken.gif (989 Byte) Low capacitance and low inductance design
haken.gif (989 Byte) Suitable for direct current and technical frequencies
haken.gif (989 Byte) High stability < ± 0.01 % over years
Application

The 0.02 class calibrated resistors excel in their modern design and small mechanical dimensions. Their ruggedness also ensures a long life.

Calibration resistors of the 1240 series are used wherever very constant operating standards are required. Typical main areas of application therefore include:

haken.gif (989 Byte) when normal resistors prove to be too large
haken.gif (989 Byte) to test measuring bridges
haken.gif (989 Byte) for tests on electrical temperature measuring equipment
haken.gif (989 Byte) for laboratory setup of a Wheatstone bridge
haken.gif (989 Byte) to setup plate circuits
haken.gif (989 Byte) for a defined current characteristic at a defined voltage
haken.gif (989 Byte) as shunt resistor for current measurement
haken.gif (989 Byte) as part of standard equipment in research laboratories
haken.gif (989 Byte) for a large part of measurements in calibration workshop.

With the delivery of this calibration resistor you get a test certificate corresponding ISO 9000 with detailed technical data.

DKD Calibration Certificate

burster präzisionsmeßtechnik at Gernsbach have set up a calibration centre for electrical quantities, connected to the German Calibration Service (DKD). This calibration centre is supervised by the Physikalisch-Technische-Bundesanstalt (PTB) at Braunschweig and is entitled to issue calibration certificates. The measurement results and uncertainties contained in the calibration certificate are obtained by using standards and measurement instruments subject to regular comparison with state standards of the Federal Rebuplic of Germany and are therefore constant with these. The proof of state control exists in the form of the calibration certificate itself and in a calibration mark which is put on the test piece. The resistor described can be supplied with a DKD Calibration Certificate.

DKD Calibration Certificate for a calibrated
resistor of series 1240

Order code 12DKD-1240

Manufacturer Calibration Certificate

Please refer to DKD Calibration Certificate but with reduced accuracy.
The traceability of the used secondary voltage and resistance standards to the national standards according to DIN ISO 9000ff is guaranteed by our certified calibration laboratory
(DKD-02101)

type 12WKS-1240
Contact: Edgar Bender +49-7224-645-19 /  e-mail: edgar.bender@burster.de