The
precision pressure transducers of this type are of a
sturdy and compact construction. They are low-priced
and can be supplied to operate in many measuring
ranges. Because of their favourable technical data and
a high degree of reliability they offer an interesting
alternative to pressure measuring applications in all
fields of machine construction, process engineering,
aeronautics and astronautics.
The
pressure transducers are easy to handle and immune to
shock loads and vibrations as they are constructed
without moving parts. They have a small dead volume.
Their design makes them well suitable for both dynamic
and static measuring performances, with the media
being either liquid or gaseous. Measuring element and
transducer housing ≥ 0 ... 50 bar are made of
one piece of stainless steel. This guarantees absolute
impermeability and insensitivity against aggressive
media. For pressure transducers with ranges < 0 ...
20 bar critical media can cause damages in the area of
the sensor body’s welding seams. In this case please
contact us.
All
pressure transducers without an internal amplifier
have a standardized sensitivity of 1.0 mV/V. This
enables the user to exchange i.e. the transducers in a
measuring chain as he likes it and consequently the
following electronic has not to be readjusted every
time. Differential pressures can be measured with only
one signal conditioner as well. Customized design is
feasible upon request.
|
| Description |
 |
The
measuring element of the precision pressure transducer
consists in a diaphragm. On its reverse side a strain
gage rosette is applied, which is an assembly of 4
active resistance strain gages arranged in a bridge
circuit. The pressure measurement is effected against
atmosphere, that means the space behind the diaphragm
is connected to the surrounding air pressure via a
small outlet in the housing. The surrounding
atmosphere has to be clean and dry. The medium to be
measured is led via the pressure port onto the
diaphragm.
As a result of pressure acting on the diaphragm it is
deformed and consequently the resistance of the strain
gages is changed. By applying a voltage to the strain
gage bridge the resistance change is transformed into
an output voltage which is directly proportional to
the pressure.
Each
transducer is available with an internal amplifier, a
socalled pressure transmitter with a voltage or a
current output.
The input of the internal amplifier is shielded
against incorrect polarity and the output against
voltage surge. The amplifier circuitry is constructed
in a way that also low-prized power supply units can
be used. The electrical connection is generated by a
MJIL-specified housing plug. The
pressure port is formed by an M 16 x 1.5 metric female
thread with sealing ring slot, and with the help of
adaptors, part of our product range, the pressure port
can be changed.
|