| Rough environment no
more problem for amplifier
(37kB)
| Product Responsibility: |
Marco Völlinger |
Telephone: +49 - 7224 - 645 - 18 |
| Marketing / Media: |
Christina Strohm |
Telephone: +49 - 7224 - 645 - 85 |

The
wide-spread burster amplifier module model 9243 for strain gauge and poten-tiometric
sensors has now been topped by its IP 65 version. The sturdy metal housing can be bolted
at any place of the used machine or equipment. The sensor and output signal will be led
directly to the corresponding clamps by means of water-proof sealings.
The stimulation voltage for the sensor will of course be
available. The balancing can be installed by the user himself. For this purpose a dip
switch can be used on which zero point, amplification, limiting frequency and stimulation
voltage are adjustable. By the aid of two setting regulators, a fine balancing is
possible. At the exit of the amplifier there are three norm signals to be used
simultaneously. While the ranges ± 5 V and ± 10 V are located on a separate clamp, there
is a third one between 0-20 mA and 4-20 mA that is switchable. The mass grindings between
measuring channels and the 24V stimulation voltage of which technicians are afraid, can be
excluded by potential separation.


|