Quality
assurance requirements for press-fit and joining processes often demand
unbroken quality demonstration records. Likewise it is a major issue –
especially during the starting period of machines – to get an outline of the
development of the entire process, so that at worst case precise
countermeasures can be applied. Already the visual impression of a set of
curves generated by the singular curves of many parts allows a lot of
conclusions.
Users
of the force-displacement controller DIGIFORCE® 9310 – the
little sprout of burster’s successful DIGIFORCE® family – have
now access to such a tool. DigiControl 9310 represents a windows software,
that besides the already known functions “backup” and “setup” now also
supports the automatic recording of measurement results, and this without any
problems for up to a dozen measurement devices in one production line.
The
user can choose amongst various formats of measurement data editing. For
statistical observation significant values such as curve entry and exit values
of the evaluation windows can be stored in an excel file, where all DIGIFORCE®-acquired
values of one press-fit process respectively of one part are shown in one
line. Each column is assigned to a special characteristic. Thus it is possible
for example to look at the diversification of the final force values of many
thousands parts.
Furthermore
a separate protocol can be generated for each part. This protocol shows the
evaluation results including measuring curve with evaluation windows
respectively envelope. For assembly units in which i.e. several press-fit
operations are controlled by multiple DIGIFORCE®s
a so-called group protocol can be generated, resuming the individual results
of all press-fit operations belonging to the given assembly unit. Later-on a
comfortable browser function enables the user to relocate those protocols very
fast by means of the assigned serial number. This serial number either had
been self-generated in advance by the software with reference to selectable
criteria or it is provided by the higher-ranking control of the serial
interface.


|