DIGISTANT® 4463 High-precision calibration source for voltage, current and thermocouple and resistance

Our calibration source is the smart, convenient and traceable answer to your calibration requirements. The DIGISTANT® 4463 enables fully automated test and simulation sequences for your measuring equipment or transducers.

  • Features

    • DC voltage up to ±100.0000 V, ±0.002 %
    • DC current up to ±50.0000 mA, ±0.005 %
    • Thermocouple simulation of R, S, B, J, T, E, K, N, M, C, D, G2
    • Automatic sequence function (ramp function) 
  • Product data

    Model 4463
    DC voltage simulation

    300 mV
    3 V
    30 V
    100 V

    Measurement accuracy voltage simulation 0.002 %
    DC voltage measurement No
    DC current simulation

    25 mA
    50 mA

    Measurement accuracy current simulation 0.005 %
    DC current measurement No
    Thermocouples simulation and measurement Yes
    RTD simulation and measurement Yes
    Interfaces RS232
    Ethernet
    USB
    Supply voltage

    230 V / 50/60 Hz
    115 V / 50/60 Hz

    Specific characteristics
    • DC voltage up to ±100.0000 V, ±0.002 %
    • DC current up to ±50.0000 mA, ±0.005 %
    • Thermocouple simulation of R, S, B, J, T, E, K, N, M, C, D, G2
    • Automatic sequence function (ramp function) 
  • Description

    This high-precision calibration source is able to measure currents up to ±50 mA, voltages ±100 V and temperature setpoint values of 12 thermocouple types, including R, S, B, J, T, E, K and N. Voltage drops across the measuring leads can be easily compensated via the sense line.

    With “thermoelectric voltage simulation” you can enter °C, °F and K, the temperature scales ITS-90 or IPTS-68 and the reference junction type constant/external. Furthermore, when simulating thermocouples a calibrated external reference junction can be used, with the calibration data being taken into account in the device.

    The high-resolution display and very user-friendly menu navigation system informs you quickly and in full detail about the selected function, the selected transmission value, the selected interface and the additional parameters.

    The device can be operated both via the keypad and via the Ethernet and USB interface.

    With the automatic sequence function (ramp function), for each measurement 32 sequences with a maximum of 100 steps can be saved and started manually or via the interface.