8411 Subminiature load cell

Very compact, small dimensions, robust, resistant, for tensile and compressive forces, stainless steel

  • Features

    • Very small dimensions
    • Robust construction
    • Made of stainless steel
    • High resonance frequency
    • For tensile and compressive forces
    • Characteristic curve deviation < 0.5% F.S.
  • Product data

    Model 8411
    Measuring range

    0 … 2,5 N
    0 … 5 N
    0 … 10 N
    0 … 20 N
    0 … 50 N
    0 … 100 N
    0 … 200 N
    0 … 500 N
    0 … 1000 N
    0 … 2000 N
    0 … 5000 N

    Direction of force Tension and compression
    Standardization Option
    Signal output

    2 mV/V
    15 mV/V
    depending on measuring range

    Protection class IP54
    Overload protection No
    Pull-plate No
    Load introduction button No
    Range of operating temperature -55 ... +120 °C
    Specific characteristics
    • Very small dimensions
    • Robust construction
    • Made of stainless steel
    • High resonance frequency
    • Characteristic curve deviation < 0.5% F.S.
  • Description

    The sensors series 8411 have deliberately been given small dimensions, so that they can easily be incorporated into existing structures or fitted into locations where access is difficult. Tensile and compressive forces are introduced to the cylindrical sensor housing through the two threaded bolts. Typical applications for these subminiature load cells include their use as measuring devices in equipment construction in general, in production lines, in measurement and control equipment, test equipment and so forth.

    The sensor is to be carefully screwed into place using the threaded bolts. Tools must not be used for assembly.

    The force must only be applied centrally, along the center line, and only through the threads. Other fitted parts must not touch the sensor housing; it is recommended that adhesive is applied to the threads. Bending, flexing or torsion forces will cause errors in the measurements and can damage the sensor. To avoid overload during assembly, it is helpful if electrical connections are made to the sensor beforehand and if the measurement on the display is watched during the process.

    The forces to be measured are applied centrally to the load cell through the two threaded pins. One covering surface of the cylindrical sensor housing is implemented as a measuring element, with the strain gauge being applied to its inner side. Under the influence of force, the full bridge circuit is unbalanced, and an output signal proportional to the force is generated.

    A rigid compensation circuit board, 7 mm wide and 70 mmlong, is located in the connecting cable to the sensor about 900 mm from the sensor body. This contains a resistor network for balancing the bridge and for temperature compensation. Removing the circuit board, or changing the cable length, will disturb the sensor‘s calibration figures.

    The strong, rigid design leads to high natural frequencies up to 160 kHz as a result, which is beneficial for dynamic measurements. The active side is the thread next to the cable.

  • Data Sheet & Downloads

    Data sheet
    Brochure
    Further info
  • Accessories

    pdf Rod ends with internal/external thread for force introduction

Product Inquiry

    Product comparison

      Amplifier module 9250
      Bus controller 9251

      • Outstanding system with up to 8 modules, expandable fieldbus interface via the bus controller
      • Supports Ethernet based fieldbuses as PROFINET, EtherCAT, EtherNet/IP or I/O interface

      Discover the universal diversity of this innovation ...