during continuous mass production
The requirement is to test the characteristic curve of micro-switches on the production line. This quality assurance measure requires a load cell with overall height and overload protection, which safeguards the load cell from damage caused by an inadmissibly high operating force in a faulty switch. A set-screw limiting the travel of the 8511 load cell provides overload protection. The measurement displacement is measured alongside the operating force, and the force/displacement curve analyzed by a DIGIFORCE® 9311 connected to the sensors.
Watch our Installation video at: <link http: www.youtube.com burstervideo _blank external link in new>www.youtube.com/bursterVideo
Go to product 8510
Go to product 8511
Go to product DIGIFORCE® 9311