Multi-axis force measurement

in tire test machines

Vehicle tire testing places particular demands on our load cells.

Calibration Instruments

Model
Calibration instrument
7281
Mobile high-precision calibrator and testing device for mechanical and electrical measurements

Measurement accuracy: < ± 0.001 % F.S.

9206
USB multisensor interface

Measurement accuracy: 0,01 % v.E.

Sample rate: 1200/s

Type of sensor: Strain gauge; Potentiometer; DC/DC; Pt100

9405
Strain gauge simulator

Bridge resistance: 350 Ω ± 1 %

Calibration steps: (±) 0; 0.5; 1; 1.5; 2; 3 mV/V

Electrical connection: 4 mm ...

72-9206-REF
Portable Precision USB Sensor Interface

Messrate: 1200/s

Sensortyp: Strain gauge; potentiometric; DC/DC; Pt100

72-REF
Portable Reference Measuring Chain with DKD/DAkkS Calibration Certificate for Compression Load from 20 N to 100 kN

Measurement accuracy: < ± 0.001 % ...

1240
Calibration resistor

Resistance value: 10 μΩ ... 100 kΩ

Tolerance: < ± 0.02 %

Temperature coefficient: ≤ ± 10 ppm/K

Storage stability: < ± 0.01 % over years

1282
Precision high capacity resistor

Resistance value: 1 mΩ ... 100 mΩ

Tolerance: 0.02 %

Temperature coefficient: ≤ ± 10 ppm/K

Storage stability: < 0.01 % over years

114X
116X
High-precision resistors

Resistance value: 5 Ω ... 100 kΩ

Tolerance: ± 0.02 % or ± 0.05 %

Temperature coefficient: < ± 10 ppm/K

Storage stability: 0.02 % over years

1144-Pt
1146-Pt
Platinum Resistance Thermometer Simulation

Temperature values: -200 ... +800 °C 

Tolerance: ± 0.02 % or ± 0.05 %

Temperature coefficient: < ± 10 ppm/K

werkskalibrierschein wks kalibrierschein vor ort on site kalibrierung factory calibration burster
72KME
Portable Load Cell Calibration

You can calibrate your load cells and load cell based measurement systems with our Portable Load Cell Calibration Stand. It measures with ...

1427
Computer-controlled high-precision resistance decade

Resistance range: 1.0000 ... 1.200000 MΩ

Tolerance: 0.005 %

1406
1407
High-precision resistance decade and calibrator

Resistance range: 10 mΩ ... 1 MΩ

Tolerance: from 0.02 %

Temperature coefficient: ≤ 10 ppm/K

Storage stability: < 0.02 % over years

4530
Precision RTD simulator

Pt100 simulation range: -200.000 ... 850.000 °C

Measurement accuracy: 0.02 °C

Pt200, Pt500, Pt1000 simulation: Yes

4501
Digital Pt100 simulator

Pt100 simulation range: -100 ... +500 °C

Measurement accuracy: ± 0.5 K

Pt200, Pt500, Pt1000 simulation: No

Ni100, Ni100 simulation: No

4506
4506S
Precision Pt100 simulator

Pt100 simulation range: -100 ... +500 °C

Measurement accuracy: ± (0.082 + 0.0003 x t) in °C

4462
High-precision calibration source for voltage, current and thermocouple

DC voltage simulation: 1 μV ... 30 V
(60 V)

4420
Universal calibrator

DC voltage simulation: ±9.999 mV ... ±11.000 V

Measurement accuracy voltage simulation: ≤ 0.02 % F.S.

4423
Documenting universal calibrator

Product no longer available.

We recommend DIGISTANT® 4420 and/or TRANS CAL 7281 depending on your application.

Product Inquiry

    Product comparison

      Discover our new brochure Load cells for production, automation, R&D and quality assurance with many application examples and product focused information!

      Download our new brochure

      © 2018 // burster präzisionsmesstechnik gmbh & co kg