Measuring range: ±500 N ... ±200 kN
Direction of force: Tension and compression
Relative non-linearity: ≤ ±0.1 % F.S. (option)
burster TEDS optionally available
Measuring range: ±2.5 N ... ±100 kN
Direction of force: Tension and compression
Relative non-linearity: ≤ ±0.15 % F.S.
burster TEDS optionally available
Measuring range: 100 N ... 1 MN
Direction of force: Compression
Relative non-linearity: ≤ ±0.1 % F.S. (option)
burster TEDS optionally available
Measuring range: 1 kN ... 100 kN
Direction of force: Compression
Relative non-linearity: ≤ ±0.25 % F.S.
Dual-range optionally
burster TEDS optionally available
Measuring range: 20 N ... 5 kN
Direction of force: Compression
Relative non-linearity: ≤ ±0.15 % F.S. (option)
Standardization: Option
burster TEDS optionally available
Measuring range: 500 N ... 100 kN
Direction of force: Compression
Relative non-linearity: ≤ ±0.035 % F.S.
burster TEDS optionally available
Measuring range: 100 N ... 200 kN
Direction of force: Compression
Relative non-linearity: ≤ ±0.5 % F.S.
burster TEDS optionally available
Measuring range: 5 N ... 5 kN
Direction of force: Compression
Relative non-linearity: ≤ ±0.25 % F.S.
Standardization: Option
burster TEDS optionally available
Measuring range: ±20 N ... ±5 kN
Direction of force: Tension and compression
Relative non-linearity: ≤ ± 0.15 % F.S.
burster TEDS optionally available
Measuring range: 500 N ... 100 kN
Direction of force: Compression
Relative non-linearity: ≤ ±0.25 % F.S.
burster TEDS optionally available
Measuring range: 100 N ... 25 kN
Direction of force: Compression
Relative non-linearity: ≤ ±0.75 % F.S.
burster TEDS optionally available
Measuring range: 500 N ... 20 kN
Direction of force: Compression
Relative non-linearity: ≤ ±1.0 % F.S.
burster TEDS optionally available
Measuring range: 200 N ... 5 kN
Direction of force: Compression
Relative non-linearity: ≤ ±0.15 % F.S.
burster TEDS optionally available
Measuring range: ±200 N ... ±5 kN
Direction of force: Tension and compression
Relative non-linearity: ≤ ±0.25 % F.S.
burster TEDS optionally available
Measuring range: ±10 N ... ±5 kN
Direction of force: Tension and compression
Relative non-linearity: ≤ ±0.5 % F.S.
burster TEDS optionally available
Measuring range: ±1 N ... ±20 N
Direction of force: Tension and compression
Relative non-linearity: ≤ ±0.2 % F.S.
burster TEDS optionally available
Measuring range: ±5 N ... ±2 kN
Direction of force: Tension and compression
Relative non-linearity: ≤ ±0.1 % F.S.
burster TEDS optionally available
Measuring range: ±20 N ... ±880 N
Direction of force: Tension and compression
Relative non-linearity: ≤ ±0.25 % F.S.
burster TEDS optionally available
Measuring range: 500 N ... 20 kN
Protection class: Sensor: IP60
burster TEDS optionally available
Flexibly configurable
3 forces / 3 torques
(Fx / Fy / Fz - Mx / My / Mz)
Robot flange according to DIN ISO 9049-1
Measuring range: 0 ... ±4448 N / 0 ... ±2224 N; 0 ... ±8896 N / 0 ... ±4448 N
Direction of force: Tension and compression
Relative non-linearity: ≤ ±0.1 % F.S.
Measuring range: ±20 N ... ±10 kN
Direction of force: Tension and compression
Relative non-linearity: ≤ ±0.5 % F.S.
Measurement range: 0 ... 2000 N
Linearity < 0.5 % F.S.
Simple handling
Principle: Rotating
Measuring range: 0.02 N·m ... 1000 N·m
Relative non-linearity: ≤ ±0.05 % F.S.
Output signal: ±10 V / ±5 V / USB
Principle: Rotating
Measuring range: 1 N·m ... 100 N·m
Relative non-linearity: ≤ ±0.2 % F.S.
Output signal: ±10 V / USB
Principle: Rotating
Measuring range: 100 N·m ... 5000 N·m
Relative non-linearity: ≤ ±0.1 % F.S.
Output signal: ±10 V / RS 422 / USB
Principle: Rotating
Measuring range: 1 N·m ... 160 N·m
Relative non-linearity: ≤ ±0.25 % F.S.
Output signal: ±10 V / USB
Principle: Non-rotating
Measuring range: 0.01 N·m ... 200 N·m
Relative non-linearity: ≤ ±0.05 % F.S.
Output signal: ±10 V / USB / mV/V
Principle: Non-rotating
Measuring range: 2 N·m ... 200 N·m
Relative non-linearity: ≤ ±0.1 % F.S.
Output signal: ±10 V / USB / mV/V
Principle: Non-rotating
Measuring range: 5 N·m ... 200 N·m
Relative non-linearity: ≤ ±0.1 % F.S.
Output signal: ±10 V / USB / mV/V
Principle: Non-rotating
Measuring range: 500 N·m ... 5000 N·m
Relative non-linearity: ≤ ±0.1 % F.S.
Signal output: mV/V
Principle: Rotating
Measuring range: 500 N·m … 1000 N·m
Relative non-linearity: ≤ ±0.1 % F.S.
Signal output: mV/V
Principle: Inductive
Measuring range: 1 mm ... 25 mm
Return spring: Yes
Principle: Inductive
Measuring range: 1 mm ... 150 mm
Measurement accuracy: < 0.25 % F.S.
Return spring: No / Yes
Principle: Inductive
Measuring range: ±1,27 mm ... ±76,2 mm
Return spring: Yes
Principle: Inductive
Measuring range: ±1.27 mm ... ±82.5 mm
Return spring: No
Principle: Potentiometric
Measuring range: 25 mm ... 250 mm
Return spring: No
Principle: Potentiometric
Measuring range: 25 mm ... 150 mm
Return spring: No
Principle: Potentiometric
Measuring range: 10 mm ... 150 mm
Return spring: Yes
Principle: Potentiometric
Measuring range: 100 mm ... 2000 mm
Measurement accuracy: ≥ ±0.05 % F.S.
Return spring: No
Principle: Potentiometric
Measuring range: 50 mm ... 900 mm
Measurement accuracy: ≥ ±0.05 % F.S.
Return spring: No
Principle: Incremental
Measuring range: 25 mm ... 100 mm
Return spring: Yes
Principle: Incremental
Measuring range: 5 mm ... 12 mm
Return spring: Yes
Principle: Incremental
Measuring range: 0 mm ... 30 mm
Return spring: Yes
Measuring range: 5 bar ... 1000 bar
Kind of measurement: Relative pressure
Measurement accuracy: < ±0.25 % F.S.
Measuring range: 0.05 bar ... 500 bar
Kind of measurement: Absolute pressure; relative pressure
Measurement accuracy: ≤ ±0.25 % F.S.
Measuring range: 0.1 bar ... 200 bar
Kind of measurement: Absolute pressure; relative pressure
Measurement accuracy: ≤ ±0.05 % F.S.
Measuring range: 30 bar ... 500 bar
Kind of measurement: Relative pressure
Measurement accuracy: ≤ ±0.1 % F.S.
Measuring range: 1 kbar ... 5 kbar
Kind of measurement: Relative pressure
Measurement accuracy: ≤ ±0.2 % F.S.
Measuring range: 5 bar ... 1000 bar
Kind of measurement: Relative pressure, against sealed atmosphere
Measurement accuracy: ≤ ±0.5 % F.S.
Measuring range: ±50 mbar ... ±10 bar
Kind of measurement: Differential
Measurement accuracy: ≤ ±0.5 % F.S.
Principle: Potentiometric
Measuring range: 350° depending on the model
Non-linearity: from ± 0.5 % F.S.