DIGISTANT® 4463 High-precision multifunction calibrator for voltage, current, thermocouples, RTDs, resistance and frequency

Our calibration source is the smart, convenient and traceable answer to your calibration requirements. The DIGISTANT® 4463 enables fully automated test and simulation sequences for your measuring equipment or transducers.

  • Features

    • DC voltage ±100 nV … ±100 V (accuracy from 0.002 %)
    • DC current ±100 nA … ±50 mA (accuracy 0.005 % ±1 µA)
    • 12 thermocouple types (accuracy from 0.1 K)
    • 32 automatic ramp functions per measured variable, each with 100 values
    • LabView driver for software integration
  • Product data

    Model 4463
    DC voltage simulation

    ±300 mV
    ±3 V
    ±30 V
    ±100 V

    Measurement accuracy voltage simulation ±0.002 %
    DC voltage measurement No
    DC current simulation

    ±25 mA
    ±50 mA

    Measurement accuracy current simulation ±0.005 % ±1 µA
    DC current measurement No
    Thermocouples simulation and measurement Yes
    RTD simulation and measurement Yes
    Interfaces RS-232 (D-sub 9)
    USB slave port (type B)
    Ethernet Western socket (RJ45)
    Supply voltage

    230 V ±10 % / 47 ... 63 Hz
    115 V ±10 % / 47 ... 63 Hz

    Specific characteristics

    • DC voltage ±100 nV … ±100 V (accuracy from 0.002 %)
    • DC current ±100 nA … ±50 mA (accuracy 0.005 % ±1 µA)
    • 12 thermocouple types (accuracy from 0.1 K)
    • 32 automatic ramp functions per measured variable, each with 100 values
    • LabView driver for software integration
  • Description

    The DIGISTANT® model 4463 is a high-precision calibration source with impressive versatility and accuracy. Every device is supplied with a DAkkS certificate. Compared to other calibrators, it offers a better error limit of 0.002 % across the entire voltage range.

    To achieve consistently high quality levels and conform to standards and regulations, measuring instruments of all kinds require regular calibration. The DIGISTANT® model 4463 provides many of the functions needed for this purpose. Inaccuracies caused by the measuring leads can be compensated via sense lines using 4-wire technology.

    All relevant information about the parameter settings and the accuracy being achieved is clearly laid out on the high-resolution color display. The dynamic menu system is navigated intuitively. Range selection is automatic or manual. Values can be entered precisely using the numeric or cursor keypad.

    The device can be controlled via its Ethernet, USB or RS-232 port. LabView drivers for software integration are available free of charge. SCPI commands are listed in the user manual. 32 ramp functions per range with 100 value/time sequences can be automatically saved and started.

    For thermocouples, scales including ITS-90 and IPTS-68, reference junction type constant or external, can be selected. An optionally available external Pt100 reference junction with calibration data taken into account in the device minimizes thermal EMFs and results in even smaller uncertainties in the measurement chain.

  • Data Sheet & Downloads

    Data sheet
    Software
    Further info
    Operation manual
  • Accessories

    pdf Mounting kit für 19"/5HE control cabinet installation
    pdf External reference junction for thermocouples Model 4485-V001


burster in Germany

burster praezisionsmesstechnik gmbh & co kg
+49 7224645-0
infoburster.com
www.burster.com

Company-Information Company-Information

Germany

burster praezisionsmesstechnik gmbh & co kg

Talstr. 1-5
76593 Gernsbach
Germany

Fon: +49 7224645-0
Fax: +49 7224645-88
infoburster.com
www.burster.com

Trade fairs

Motek
05.10. - 08.10.21 - Stuttgart, 70269, Germany  

×
© 2020 // burster präzisionsmesstechnik gmbh & co kg
nach